RG-SF2920-8GT2XMG2XS-P
RG-SF2920-8GT2XMG2XS-P
RG-SF2920-8GT2XMG2XS-P
RG-SF2920-8GT2XMG2XS-P
RG-SF2920-8GT2XMG2XS-P
RG-SF2920-8GT2XMG2XS-P
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾
¼ÓÔØÖÐ...0%
ͼƬ

8¿ÚǧÕ×ÒÔ̫ȫ¹âÍøÂçÈëÊÒPoE½»Á÷»ú£¬£¬£¬£¬£¬2¸öÍòÕ×ÉÏÐйâ¿Ú£¬£¬£¬£¬£¬RG-SF2920-8GT2XMG2XS-P

ÊÊÓÃÓÚ½ÌÓý¡¢Ò½ÁÆ¡¢ÆóÒµ¼¶ºÍÉÌÓÿͻ§µÄÖǻۿÎÌᢶàýÌå¿ÎÌᢰ칫ÊÒ¡¢ÕïÊÒ²¡·¿¡¢Î¢ÐÍ·ÖÖ§»ú¹¹ÒÔ¼°ÆäËüÅäÏßÊÜÏÞµÄÇéÐÎÖУ¬£¬£¬£¬£¬ÎªÎÞÏß¡¢³¬ÇåÊý×ÖÊÓÆµÉãÏñÍ·¡¢ÖÇÄܵç×Ó´²Í·ÆÁµÈº£Á¿ÎïÁªÖÕ¶ËºÍÆäËûIPÐÅÏ¢µãλÌṩ¾Í½ü½ÓÈëÒÔ¼°³¬´ó´ø¿í¡£¡£¡£¡£¡£

²úÆ·ÌØÕ÷£º

  • С³ß´ç£¬£¬£¬£¬£¬²»±ØÈû£¬£¬£¬£¬£¬ÈëÊÒÑŹ۸ü¶¨ÐÄ
  • Á¢ÒìöèÓã÷¢Íâ¿ÇÉè¼Æ£¬£¬£¬£¬£¬É¢ÈÈÐÔÄÜÌáÉý
  • ÎÞµçÉÈ£¬£¬£¬£¬£¬×ÔȻɢÈÈ£¬£¬£¬£¬£¬¾²ÒôÓÖ½ÚÄÜ
  • ×ÔÁ¦¹âÄ£¿ £¿£¿£¿£¿£¿ £¿éÉè¼Æ£¬£¬£¬£¬£¬¿É¿¿ÐÔÉý¼¶£¬£¬£¬£¬£¬Êý¾Ýת·¢¸üÎȹÌ
  • ¡°Ò»»úË«Íø¡±Éè¼Æ£¬£¬£¬£¬£¬Ò»Ì廯°²ÅÅ£¬£¬£¬£¬£¬¸üÇáËÉʵÏÖÄÚÍâÍøÎïÀí¸ôÀë
  • ´îÅäSDN¿ØÖÆÆ÷ £¬£¬£¬£¬£¬ÊµÏÖ¼«¼òÔËά£¬£¬£¬£¬£¬ÔËά¹ÜÀí¼òÆÓ¸ßЧ"
Á¬Ã¦×Éѯ

¼«¼ò¹âÈëÊÒ½»Á÷»ú RG-SF2920-8GT2XMG2XS-P

½ÓÄÉÒÔÌ«Íø¼Ü¹¹+ȫйâÏËÈëÊҵݲÅÅ·½·¨£¬£¬£¬£¬£¬ÊµÏÖÍòÕ×È«¹âÈëÊÒ£¬£¬£¬£¬£¬½Ó¿Ú¸»ºñ£¬£¬£¬£¬£¬ËÙÂÊÉý¼¶£¬£¬£¬£¬£¬Ö§³ÖPoE++¹©µç£¬£¬£¬£¬£¬ÓªÒµÖÜÈ«ÍØÕ¹

Stake(ÖйúÇø)¹Ù·½ÍøÕ¾
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾
Á¢ÒìöèÓã÷¢Íâ¿ÇÉè¼Æ£¬£¬£¬£¬£¬É¢ÈÈÐÔÄÜÌáÉý
È«ÐÂöèÓã÷¢¡¢Ñ¹ÖýÒ»Ì廯Íâ¿ÇÉè¼Æ£¬£¬£¬£¬£¬É¢ÈÈÃæ»ýÌáÉý37%£¬£¬£¬£¬£¬Çå¾²¡¢ÑŹÛÈÚÈëÈõµçÏä
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾
ÎÞµçÉÈ£¬£¬£¬£¬£¬×ÔȻɢÈÈ£¬£¬£¬£¬£¬¾²ÒôÓÖ½ÚÄÜ
ÎÞµçÉÈÉè¼Æ£¬£¬£¬£¬£¬×ÔȻɢÈÈ£¬£¬£¬£¬£¬¼È°ü¹Ü×°±¸³¤Ê±¼äÔËÐÐÎÞ¸ÐÖª£¬£¬£¬£¬£¬ÓÖÃâÈ¥ÁËÔëÒô·³ÈÅ£¬£¬£¬£¬£¬¸ü¾²ÒôµØÊµÏÖǧÕ×µ½×ÀÃæ
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾
×ÔÁ¦¹âÄ£¿ £¿£¿£¿£¿£¿ £¿éÉè¼Æ£¬£¬£¬£¬£¬¿É¿¿ÐÔÉý¼¶£¬£¬£¬£¬£¬Êý¾Ýת·¢¸üÎȹÌ
ÒÔ̫ȫ¹âÍøÂç½ÓÄɵã¶Ôµã´«Ê䣬£¬£¬£¬£¬Ìṩ¸üΪ¿É¿¿µÄ×ÔÁ¦¹âÄ£¿ £¿£¿£¿£¿£¿ £¿éÉè¼Æ£¬£¬£¬£¬£¬¸ßÖÊÁ¿ÐźŴ«Êä²»ÊÜÍâ½ç×ÌÈÅ£¬£¬£¬£¬£¬Êý¾Ýת·¢¸üÎȹÌ
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾
“Ò»»úË«Íø”Éè¼Æ£¬£¬£¬£¬£¬Ò»Ì廯°²ÅÅ£¬£¬£¬£¬£¬¸üÇáËÉʵÏÖÄÚÍâÍøÎïÀí¸ôÀë
×éºÏ2¿ÚÆ´½ÓÍØÕ¹Ä£¿ £¿£¿£¿£¿£¿ £¿é£¬£¬£¬£¬£¬ÊµÏÖÁ½ÕÅÎïÀíÍøÂçÔړһ̨”×°±¸Éϰ²ÅÅ¡¢×°Öú͹ÜÀí¡£¡£¡£¡£¡£½µµÍ°²ÅÅÄѶÈ£¬£¬£¬£¬£¬¸üÇáËÉʵÏÖÄÚÍâÍøÎïÀí¸ôÀ룬£¬£¬£¬£¬Í¬Ê±ÖúÁ¦Ò½ÔºÍ¨¹ýµÈ±£2.0
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾
SDNͳһ¹ÜÀíÆ½Ì¨£¬£¬£¬£¬£¬ÊµÏÖ±ã½Ý¹ÜÀí
Ö§³ÖÁãÉèÖÃÌæ»»¡¢Ö§³Ö¶Ë¿Úä²å¡¢Ö§³Ö»·Â·¼ì²â£¬£¬£¬£¬£¬Ö§³Ö¹âÁ´Â·¼ì²â£¬£¬£¬£¬£¬Ö§³Ö×°±¸ÍøÂç״̬Õï¶Ï
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾

Äú¾õÊÊÄ¿½ñÄÚÈÝÖÊÁ¿ÔõÑù£¿ £¿£¿£¿£¿£¿ £¿

²»Õ¦µÎ ºÜÊǺÃ

Äú¸ø³ö¸Ã·ÖÊýµÄÖ÷ÒªÔµ¹ÊÔ­ÓÉÊÇʲô£¿ £¿£¿£¿£¿£¿ £¿

ллÄúµÄÆÀ¼Û,ÎÒÃÇ»á½øÒ»²½Ë¢ÐÂÒÔÁè¼ÝÄúµÄÆÚÍû¡£¡£¡£¡£¡£

Stake(ÖйúÇø)¹Ù·½ÍøÕ¾
Äú¾õÊÊÄ¿½ñÄÚÈÝÖÊÁ¿ÔõÑù£¿ £¿£¿£¿£¿£¿ £¿
²»Õ¦µÎ ºÜÊǺÃ

ллÄúµÄÆÀ¼Û,ÎÒÃÇ»á½øÒ»²½Ë¢ÐÂÒÔÁè¼ÝÄúµÄÆÚÍû¡£¡£¡£¡£¡£

ÊÖÒÕ²ÎÊý

Ó²¼þ¹æ¸ñ

½Ó¿Ú¹æ¸ñ

½Ó¿Ú¹æ¸ñ RG-SF2920-8GT4XS RG-SF2920-8GT2MG2XS RG-SF2920-16GT2SFP RG-SF2920-16GT2MG2XS
¹Ì»¯ÓªÒµ½Ó¿Ú 8¸ö10/100/1000M×Ô˳Ӧµç¿Ú
4¸ö1G/2.5G/10G SFP+¹â¿Ú
8¸ö10/100/1000M×Ô˳Ӧµç¿Ú
2¸ö1G/2.5G×Ô˳Ӧ¿Ú
2¸ö1G/10G SFP+¹â¿Ú
16¸ö10/100/1000M×Ô˳Ӧµç¿Ú
2¸ö1G SFP¹â¿Ú
16¸ö10/100/1000M×Ô˳Ӧµç¿Ú
2¸ö1G/2.5G×Ô˳Ӧ¿Ú
2¸ö1G/10G SFP+¹â¿Ú
½Ó¿Ú¹æ¸ñ RG-SF2920-8GT2MG2XS-P RG-SF2920-8GT2XMG2XS-P RG-SF2920-16GT2SFP-P RG-SF2920-16GT2MG2XS-P
¹Ì»¯ÓªÒµ½Ó¿Ú 8¸ö10/100/1000M×Ô˳Ӧµç¿Ú
2¸ö1G/2.5G/5G×Ô˳Ӧµç¿Ú
2¸ö1G/10G SFP+¹â¿Ú
8¸ö10/100/1000M×Ô˳Ӧµç¿Ú
2¸ö1G/2.5G/5G/10G×Ô˳Ӧ¿Ú
2¸ö1G/2.5G/10G SFP+¹â¿Ú
16¸ö10/100/1000M×Ô˳Ӧµç¿Ú
2¸ö1G SFP¹â¿Ú
16¸ö10/100/1000M×Ô˳Ӧµç¿Ú
2¸ö1G/2.5G/5G×Ô˳Ӧµç¿Ú
2¸ö1G/10G SFP+¹â¿Ú
½Ó¿Ú¹æ¸ñ RG-SF2920-16GT2XMG2XS-UP
¹Ì»¯ÓªÒµ½Ó¿Ú 16¸ö10/100/1000M×Ô˳Ӧµç¿Ú
2¸ö1G/2.5G/5G/10G×Ô˳Ӧµç¿Ú
2¸ö1G/2.5G/10G SFP+¹â¿Ú£¨2.5GÊÊÅäÇë²Î¿¼Ó²¼þ×°ÖÃÊֲᣩ

ϵͳ¹æ¸ñ

ϵͳ¹æ¸ñ RG-SF2920-8GT4XS RG-SF2920-8GT2MG2XS RG-SF2920-16GT2SFP RG-SF2920-16GT2MG2XS
½»Á÷ÈÝÁ¿ 672Gbps/6.72Tbps 672Gbps/6.72Tbps 672Gbps/6.72Tbps 672Gbps/6.72Tbps
°üת·¢ÂÊ 126Mpps 126Mpps 126Mpps 126Mpps
ϵͳ¹æ¸ñ RG-SF2920-8GT2MG2XS-P RG-SF2920-8GT2XMG2XS-P RG-SF2920-16GT2SFP-P RG-SF2920-16GT2MG2XS-P
½»Á÷ÈÝÁ¿ 672Gbps/6.72Tbps 672Gbps/6.72Tbps 672Gbps/6.72Tbps 672Gbps/6.72Tbps
°üת·¢ÂÊ 126Mpps 126Mpps 126Mpps 126Mpps
ϵͳ¹æ¸ñ RG-SF2920-16GT2XMG2XS-UP
½»Á÷ÈÝÁ¿ 672Gbps/6.72Tbps
°üת·¢ÂÊ 126Mpps

µçÔ´Ó빦ºÄ

µçÔ´Ó빦ºÄ RG-SF2920-8GT4XS RG-SF2920-8GT2MG2XS RG-SF2920-16GT2SFP RG-SF2920-16GT2MG2XS
µçÔ´ ¹Ì»¯µ¥½»Á÷µçÔ´ ¹Ì»¯µ¥½»Á÷µçÔ´ ¹Ì»¯µ¥½»Á÷µçÔ´ ¹Ì»¯µ¥½»Á÷µçÔ´
µçÔ´ÊäÈë ½»Á÷£¨AC£©ÊäÈ룺
  • ¶î¶¨µçѹ£º200V~240V

  • ×î´óµçѹ£º180V~264V

  • ƵÂÊ£º50Hz~60Hz

¸ßѹֱÁ÷£¨HVDC£©ÊäÈ룺֧³Ö
½»Á÷£¨AC£©ÊäÈ룺
  • ¶î¶¨µçѹ£º200V~240V

  • ×î´óµçѹ£º180V~264V

  • ƵÂÊ£º50Hz~60Hz

¸ßѹֱÁ÷£¨HVDC£©ÊäÈ룺֧³Ö
½»Á÷£¨AC£©ÊäÈ룺
  • ¶î¶¨µçѹ£º200V~240V

  • ×î´óµçѹ£º180V~264V

  • ƵÂÊ£º50Hz~60Hz

¸ßѹֱÁ÷£¨HVDC£©ÊäÈ룺֧³Ö
½»Á÷£¨AC£©ÊäÈ룺
  • ¶î¶¨µçѹ£º200V~240V

  • ×î´óµçѹ£º180V~264V

  • ƵÂÊ£º50Hz~60Hz

¸ßѹֱÁ÷£¨HVDC£©ÊäÈ룺֧³Ö
Õû»ú¹¦ºÄ <25W <25W <25W <25W
PoE ²»Ö§³Ö ²»Ö§³Ö ²»Ö§³Ö ²»Ö§³Ö
µçÔ´Ó빦ºÄ RG-SF2920-8GT2MG2XS-P RG-SF2920-8GT2XMG2XS-P RG-SF2920-16GT2SFP-P RG-SF2920-16GT2MG2XS-P
µçÔ´ ¹Ì»¯µ¥½»Á÷µçÔ´ ¹Ì»¯µ¥½»Á÷µçÔ´ ¹Ì»¯µ¥½»Á÷µçÔ´ ¹Ì»¯µ¥½»Á÷µçÔ´
µçÔ´ÊäÈë ½»Á÷£¨AC£©ÊäÈ룺
  • ¶î¶¨µçѹ£º200V~240V

  • ×î´óµçѹ£º180V~264V

  • ƵÂÊ£º50Hz~60Hz

¸ßѹֱÁ÷£¨HVDC£©ÊäÈ룺֧³Ö
½»Á÷£¨AC£©ÊäÈ룺
  • ¶î¶¨µçѹ£º200V~240V

  • ×î´óµçѹ£º180V~264V

  • ƵÂÊ£º50Hz~60Hz

¸ßѹֱÁ÷£¨HVDC£©ÊäÈ룺֧³Ö
½»Á÷£¨AC£©ÊäÈ룺
  • ¶î¶¨µçѹ£º200V~240V

  • ×î´óµçѹ£º180V~264V

  • ƵÂÊ£º50Hz~60Hz

¸ßѹֱÁ÷£¨HVDC£©ÊäÈ룺֧³Ö
½»Á÷£¨AC£©ÊäÈ룺
  • ¶î¶¨µçѹ£º200V~240V

  • ×î´óµçѹ£º180V~264V

  • ƵÂÊ£º50Hz~60Hz

¸ßѹֱÁ÷£¨HVDC£©ÊäÈ룺֧³Ö
Õû»ú¹¦ºÄ ²»´øPoE¸ºÔØ£º<25W
PoEÂúÔØ£º<150W
²»´øPoE¸ºÔØ£º<25W
PoEÂúÔØ£º<150W
²»´øPoE¸ºÔØ£º<25W
PoEÂúÔØ£º<150W
²»´øPoE¸ºÔØ£º<25W
PoEÂúÔØ£º<150W
PoE½Ó¿Ú 1~8ºÅµç¿ÚÖ§³ÖPoE/PoE+¹©µç 1~2ºÅµç¿ÚÖ§³ÖPoE/PoE+/PoE++¹©µç£¬£¬£¬£¬£¬3~10ºÅµç¿ÚÖ§³ÖPoE/PoE+ 1~8ºÅµç¿ÚÖ§³ÖPoE/PoE+¹©µç 1~8ºÅµç¿ÚÖ§³ÖPoE/PoE+¹©µç
PoE±ê×¼ PoE¹©µçÉè¼ÆÖ§³ÖIEEE 802.3af£¨15.4W£©¡¢IEEE 802.3at£¨30W£© PoE¹©µçÉè¼ÆÖ§³ÖIEEE 802.3af£¨15.4W£©¡¢IEEE 802.3at£¨30W£©¡¢IEEE 802.3bt£¨60W£© PoE¹©µçÉè¼ÆÖ§³ÖIEEE 802.3af£¨15.4W£©¡¢IEEE 802.3at£¨30W£© PoE¹©µçÉè¼ÆÖ§³ÖIEEE 802.3af£¨15.4W£©¡¢IEEE 802.3at£¨30W£©
PoEÊä³ö¹¦ÂÊ Õû»ú×î´ó125W Õû»ú×î´ó125W Õû»ú×î´ó125W Õû»ú×î´ó125W
PoE¹¦Ð§ Ö§³Ö×Ô¶¯¡¢½ÚÄܹ©µç¹ÜÀíģʽ
Ö§³ÖÈÈÆô¶¯²»ÖÐÖ¹¹©µç
Ö§³Ö¶Ë¿ÚÓÅÏȼ¶
Ö§³Ö¶ÔPoE¶Ë¿Ú׼ʱÉÏϵç
Ö§³Ö×Ô¶¯¡¢½ÚÄܹ©µç¹ÜÀíģʽ
Ö§³ÖÈÈÆô¶¯²»ÖÐÖ¹¹©µç
Ö§³Ö¶Ë¿ÚÓÅÏȼ¶
Ö§³Ö¶ÔPoE¶Ë¿Ú׼ʱÉÏϵç
Ö§³Ö×Ô¶¯¡¢½ÚÄܹ©µç¹ÜÀíģʽ
Ö§³ÖÈÈÆô¶¯²»ÖÐÖ¹¹©µç
Ö§³Ö¶Ë¿ÚÓÅÏȼ¶
Ö§³Ö¶ÔPoE¶Ë¿Ú׼ʱÉÏϵç
Ö§³Ö×Ô¶¯¡¢½ÚÄܹ©µç¹ÜÀíģʽ
Ö§³ÖÈÈÆô¶¯²»ÖÐÖ¹¹©µç
Ö§³Ö¶Ë¿ÚÓÅÏȼ¶
Ö§³Ö¶ÔPoE¶Ë¿Ú׼ʱÉÏϵç
µçÔ´Ó빦ºÄ RG-SF2920-16GT2XMG2XS-UP
µçÔ´ ¹Ì»¯µ¥½»Á÷µçÔ´
µçÔ´ÊäÈë ½»Á÷£¨AC£©ÊäÈ룺
  • ¶î¶¨µçѹ£º220V~240V

  • ×î´óµçѹ£º198V~264V

  • ƵÂÊ£º50Hz~60Hz

¸ßѹֱÁ÷£¨HVDC£©ÊäÈ룺֧³Ö
Õû»ú¹¦ºÄ ²»´øPoE¸ºÔØ£º<25W
PoEÂúÔØ£º<295W
PoE½Ó¿Ú 1~2ºÅµç¿ÚÖ§³ÖPoE/PoE+/PoE++¹©µç£¬£¬£¬£¬£¬µ¥¿Ú×î´ó90W£»£»£»£» £»
3~4ºÅµç¿ÚÖ§³ÖPoE/PoE+/PoE++¹©µç£¬£¬£¬£¬£¬µ¥¿Ú×î´ó60W£»£»£»£» £»
5~18ºÅµç¿ÚÖ§³ÖPoE/PoE+¹©µç£¬£¬£¬£¬£¬µ¥¿Ú×î´ó30W
PoE±ê×¼ PoE¹©µçÉè¼ÆÖ§³ÖIEEE 802.3af£¨15.4W£©¡¢IEEE 802.3at£¨30W£©¡¢IEEE 802.3bt£¨60W/90W£©
PoEÊä³ö¹¦ÂÊ Õû»ú×î´ó250W
PoE¹¦Ð§ Ö§³Ö×Ô¶¯¡¢½ÚÄܹ©µç¹ÜÀíģʽ
Ö§³ÖÈÈÆô¶¯²»ÖÐÖ¹¹©µç
Ö§³Ö¶Ë¿ÚÓÅÏȼ¶
Ö§³Ö¶ÔPoE¶Ë¿Ú׼ʱÉÏϵç

³ß´ç

³ß´ç RG-SF2920-8GT4XS RG-SF2920-8GT2MG2XS RG-SF2920-16GT2SFP RG-SF2920-16GT2MG2XS
²úÆ·³ß´ç£¨¿íxÉîx¸ß£© 210mm x 235mm x 55mm 210mm x 235mm x 55mm 210mm x 235mm x 55mm 210mm x 235mm x 55mm
³ß´ç RG-SF2920-8GT2MG2XS-P RG-SF2920-8GT2XMG2XS-P RG-SF2920-16GT2SFP-P RG-SF2920-16GT2MG2XS-P
²úÆ·³ß´ç
£¨¿íxÉîx¸ß£©
210mm x 235mm x 55mm 210mm x 235mm x 55mm 210mm x 235mm x 55mm 210mm x 235mm x 55mm
³ß´ç RG-SF2920-16GT2XMG2XS-UP
²úÆ·³ß´ç
£¨¿íxÉîx¸ß£©
210mm x 250mm x 55mm

ÇéÐÎÓë¿É¿¿ÐÔ

ÇéÐÎÓë¿É¿¿ÐÔ RG-SF2920-8GT4XS
RG-SF2920-8GT2MG2XS
RG-SF2920-16GT2SFP
RG-SF2920-16GT2MG2XS
RG-SF2920-8GT2MG2XS-P
RG-SF2920-8GT2XMG2XS-P
RG-SF2920-16GT2SFP-P
RG-SF2920-16GT2MG2XS-P
RG-SF2920-16GT2XMG2XS-UP
µçÉÈ Ö§³ÖÎÞµçÉÈ£¬£¬£¬£¬£¬×ÔȻɢÈÈ
ÎÂ¶È ÊÂÇéζȣº0¡æ~45¡æ
´æ´¢Î¶ȣº-40¡æ~70¡æ
ʪ¶È ÊÂÇéʪ¶È£º5%~95%RH
´æ´¢Êª¶È£º5%~95%RH

Èí¼þ¹æ¸ñ

Èí¼þ¹æ¸ñ RG-SF2920-8GT4XS
RG-SF2920-8GT2MG2XS
RG-SF2920-16GT2SFP
RG-SF2920-16GT2MG2XS
RG-SF2920-8GT2MG2XS-P
RG-SF2920-8GT2XMG2XS-P
RG-SF2920-16GT2SFP-P
RG-SF2920-16GT2MG2XS-P
RG-SF2920-16GT2XMG2XS-UP
STP Ö§³Ö
RSTP Ö§³Ö
MSTP Ö§³Ö
RLDP Ö§³Ö
MACµØÖ·±í Ö§³Ö¾²Ì¬MACµØÖ·
Ö§³ÖMACµØÖ·¹ýÂË
802.1Q VLAN Ö§³Ö4K 802.1Q VLAN
Ö§³ÖPort based VLAN
Ö§³ÖMAC based VLAN
Ö§³ÖPrivate VLAN
Ö§³ÖProtocol based VLAN
Ö§³ÖGVRP
Ö§³ÖVoice VLAN
QinQ Ö§³Ö»ù±¾QinQ
Ö§³ÖÎÞаQinQ
¶þ²ã»·ÍøÊÖÒÕ Ö§³ÖG.8032¹ú¼Ê±ê×¼»·ÍøÐ­ÒéERPS£¬£¬£¬£¬£¬Çл»Ê±¼ä¡Ü50ms£¬£¬£¬£¬£¬¿ÉÓëÆäËûÖ§³Ö¸ÃЭÒéµÄ²úÆ·ÍêÉÆ¼æÈÝ
¶Ë¿Ú¾ÛºÏ Ö§³ÖÁ÷Á¿Æ½ºâ·½·¨
Ö§³ÖLACP¶¯Ì¬¾ÛºÏ
Ö§³ÖLACPÓÅÏȼ¶/ЭÉÌ·½·¨ /×î´ó¿É¾ÛºÏ¿ÚÊýÄ¿ÉèÖÃ
Mirror Ö§³ÖͨË×ÓªÒµ¿Ú¡¢¾ÛºÏ¶Ë¿Ú×÷Ϊ¾µÏñµÄÔ´ÒÔ¼°Ä¿µÄ¶Ë¿Ú
Ö§³Ö»ùÓÚÁ÷¡¢»ùÓÚVLANµÄ¶Ë¿Ú¾µÏñ
Ö§³ÖÒ»¶ÔÒ»¡¢Ò»¶Ô¶à¡¢¶à¶ÔÒ»µÄ¾µÏñ£¬£¬£¬£¬£¬Ö§³ÖRSPAN¡¢ERSPAN
DHCP Ö§³ÖDHCP Server
Ö§³ÖDHCP Client
Ö§³ÖDHCP Snooping
Ö§³ÖDHCP Relay
IP·ÓÉ Ö§³Ö¾²Ì¬ºÚ¶´Â·ÓÉ¡¢RIP¡¢RIPng¡¢OSPF¡¢OSPFv3ЭÒé
ACL Ö§³Ö±ê×¼IP ACL£¨»ùÓÚIPµØÖ·µÄÓ²¼þACL£©
Ö§³ÖÀ©Õ¹IP ACL£¨»ùÓÚIPµØÖ·¡¢TCP/UDP¶Ë¿ÚºÅµÄÓ²¼þACL£©
Ö§³ÖMACÀ©Õ¹ACL£¨»ùÓÚÔ´MACµØÖ·¡¢Ä¿µÄMACµØÖ·ºÍ¿ÉÑ¡µÄÒÔÌ«ÍøÀàÐ͵ÄÓ²¼þACL£©
Ö§³Ö»ùÓÚʱ¼äACL
Ö§³ÖACL80
Ö§³ÖIPv6 ACL
Ö§³ÖÈ«¾ÖACL
Ö§³ÖACLÖØ¶¨Ïò
QoS Ö§³Ö¶Ë¿ÚÁ÷Á¿Ê¶±ð
Ö§³Ö¶Ë¿ÚÁ÷Á¿ÏÞËÙ
Ö§³Ö802.1p/DSCP/TOSÁ÷Á¿·ÖÀà
ÿ¶Ë¿Ú8¸öÓÅÏȼ¶ÐÐÁÐ
Ö§³ÖSP¡¢WRR¡¢DRR¡¢SP+WFQ¡¢ SP+WRR¡¢SP+DRR¡¢RED/WREDÐÐÁе÷Àí
Çå¾²ÌØÕ÷ ¹ýÂ˲»·¨µÄMACµØÖ·
Ö§³Ö¹ã²¥·ç±©ÒÖÖÆ
¹ÜÀíÔ±·Ö¼¶¹ÜÀíºÍ¿ÚÁî±£»£»£»£» £»¤
Ö§³ÖRADIUS ºÍ TACACS+
Ö§³ÖSSH ºÍ SSH V2.0
Ö§³ÖBPDU Guard
Ö§³ÖCPP¡¢NFPP
Ö§³Ö¶Ë¿Ú±£»£»£»£» £»¤
EEE Ö§³ÖIEEE 802.3az±ê×¼µÄEEE½ÚÄÜÊÖÒÕ£ºµ±EEEʹÄÜʱ£¬£¬£¬£¬£¬´Ó¶ø´ó·ù¶ÈµÄ¼õС¶Ë¿ÚÔڸý׶εŦºÄ£¬£¬£¬£¬£¬µÖ´ïÁ˽ÚÄܵÄÄ¿µÄ
¹ÜÀíÌØÕ÷ SNMP¡¢CLI(Telnet/Console)¡¢RMON¡¢SSH¡¢Syslog/Debug¡¢NTP/SNTP¡¢FTP¡¢TFTP¡¢Web¡¢RLDP
Õö¿ªÏêϸ²ÎÊý

Ó¦ÓôîÅä

¹âÏË
ÍøÏß
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾

Ó¦Óó¡¾°

³£¼ûÎÊÌâ

ÔÝÎÞÎÊÌ⣬£¬£¬£¬£¬ÎÒÒªÌáÎÊ
ÈôÊÇÄúÐèÒª¸ü¶à²úÆ·ÊÖÒÕ×Éѯ
ÏêϸÐÔÄÜÄÜ·ñÖª×ãÄúµÄÓªÒµ·åÖµ£¿ £¿£¿£¿£¿£¿ £¿ÔõÑùÍýÏë°²ÅÅÓëÉèÖã¿ £¿£¿£¿£¿£¿ £¿
Á¬Ã¦×Éѯ
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾

·µ»Ø¶¥²¿

ÊÕÆð
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾ ÎĵµAIÖúÊÖ
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾ ÎĵµÆÀ¼Û
¸Ã×ÊÁÏÊÇ·ñ½â¾öÁËÄúµÄÎÊÌ⣿ £¿£¿£¿£¿£¿ £¿
Äú¶ÔÄ¿½ñÒ³ÃæµÄÖª×ã¶ÈÔõÑù£¿ £¿£¿£¿£¿£¿ £¿
²»Õ¦µÎ
ºÜÊǺÃ
ÄúÖª×ãµÄÔµ¹ÊÔ­ÓÉÊÇ£¨¶àÑ¡£¡£¡£¡£¡£©£¿ £¿£¿£¿£¿£¿ £¿
Äú¶ÔÎĵµÊÇ·ñÉÐÓÐÆäËüµÄÎÊÌâ»ò½¨Ò飿 £¿£¿£¿£¿£¿ £¿
Ϊ¾¡¿ì½â¾öÎÊÌ⣬£¬£¬£¬£¬ÇëÄúÁôÏÂÁªÏµ·½·¨Òﱋȯ¸´
ÓÊÏä
ÊÖ»úºÅ
ллÄúµÄ·´Ï죡£¡£¡£¡£¡
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾
ÇëÑ¡Ôñ·þÎñÏîÄ¿
¹Ø±Õ×Éѯҳ
ÊÛǰ×Éѯ ÊÛǰ×Éѯ
ÊÛǰ×Éѯ
ÊÛºó·þÎñ ÊÛºó·þÎñ
ÊÛºó·þÎñ
Òâ¼û·´Ïì Òâ¼û·´Ïì
Òâ¼û·´Ïì
¸ü¶àÁªÏµ·½·¨
ÍøÕ¾µØÍ¼