stake¹ÙÍø

µã»÷ÏÂÔØ¡¶ÍòÕ×Ô°ÇøÒÔÌ«²Ê¹âÑо¿±¨¸æ¡·£¬£¬£¬£¬£¬ £¬½âËøÍòÕ×Ô°ÇøÍøÂ罨ÉèÖ¸ÄÏ
Á¬Ã¦ÏÂÔØ
ÎÞ¸Ð×¼Èë ÈËÎïͳ¹Ü Ø­ RG-SAM+5.X ÐÂÒ»´ú¸ßУAIÈÏ֤ƽ̨Ðû²¼
Ô¤Ô¼Ö±²¥
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾
²úÆ·
< ·µ»ØÖ÷²Ëµ¥
²úÆ·ÖÐÐÄ
²úÆ·
½â¾ö¼Æ»®
< ·µ»ØÖ÷²Ëµ¥
½â¾ö¼Æ»®ÖÐÐÄ
ÐÐÒµ
ºÏ×÷»ï°é
·µ»ØÖ÷²Ëµ¥
Ñ¡ÔñÇøÓò/ÓïÑÔ
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾
RG-S5310-24GT4XS
RG-S5310-24GT4XS
RG-S5310-24GT4XS
RG-S5310-24GT4XS
RG-S5310-24GT4XS
RG-S5310-24GT4XS
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾
¼ÓÔØÖÐ...0%
ͼƬ

24¿ÚǧÕ×µç½ÓÈë½»Á÷»ú£¬£¬£¬£¬£¬ £¬4¸öÍòÕ×ÉÏÐпڣ¬£¬£¬£¬£¬ £¬RG-S5310-24GT4XS

´óÐÍÆóÊÂÒµÔ°ÇøÄÚ¾ÖÓòÍøµÄȫǧÕ×½ÓÈ룬£¬£¬£¬£¬ £¬ÉÌҵϵͳÈçÒ½ÁÆ¡¢Í¼Êé¹Ý¡¢»áÕ¹ÖÐÐÄ¡¢ÍøÕ¾µÈǧÕ×½ÓÈ룬£¬£¬£¬£¬ £¬·þÎñÆ÷ȺµÄǧÕ×½ÓÈë

²úÆ·ÌØÕ÷£º

  • ÍêÉÆµÄÇå¾²·À»¤Õ½ÂÔ
  • ÐéÄâ½»Á÷µ¥Î»
  • ºÍstake¹ÙÍøÍøÂç×ÔÑÐSDN controller Ï໥ÅäºÏ£¬£¬£¬£¬£¬ £¬¼ò»¯ÍøÂç¹ÜÀíµÄÄѶȡ¢½µµÍÍøÂçά»¤µÄ±¾Ç®
Á¬Ã¦×Éѯ

ÍêÉÆµÄÇå¾²·À»¤Õ½ÂÔ

ARP²¡¶¾»ò¹¥»÷ÊÇÍøÂçÖкܳ£¼û£¬£¬£¬£¬£¬ £¬Í¬Ê±Ó°Ïì½Ï´óµÄÒ»À๥»÷¡£¡£¡£¡£¡£¡£RG-S5310ϵÁн»Á÷»úÖ§³Ö¶àÖÖģʽµÄARP·ÀÓÕÆ­¹¦Ð§£¬£¬£¬£¬£¬ £¬ÆñÂÛÊÇÓû§Í¨¹ýDHCP·þÎñÆ÷×Ô¶¯»ñÈ¡µØÖ·£¬£¬£¬£¬£¬ £¬ÕÕ¾ÉʹÓÃÀο¿µÄIPµØÖ·£¬£¬£¬£¬£¬ £¬RG-S5310ϵÁÐÄܹ»¼ÍÈÎÃü»§ÕæÊµµÄIP+MACµØÖ·£¬£¬£¬£¬£¬ £¬²¢ÔÚ½»Á÷»ú¶Ë¿ÚÊÕµ½Ö÷»ú·¢Ë͵ÄARP±¨ÎÄʱ£¬£¬£¬£¬£¬ £¬½«ARP±¨ÎÄÄÚÈݺͼͼµÄIP+MACµØÖ·¾ÙÐбȶԣ¬£¬£¬£¬£¬ £¬Ö»¶ÔÄÚÈÝÕæÊµµÄARP±¨ÎľÙÐÐת·¢£¬£¬£¬£¬£¬ £¬¶ÔÐéαµÄARP±¨ÎľÙÐÐÑïÆú£¬£¬£¬£¬£¬ £¬´Ó¶ø½«ARPÓÕÆ­ÆÁÕÏÔÚÍøÂçÖ®Í⣬£¬£¬£¬£¬ £¬°ü¹ÜÍøÂçÓû§ÃâÊÜARP²¡¶¾¹¥»÷¡£¡£¡£¡£¡£¡£

×Ô¶¯·ÀÓùÍøÂçÖеÄÖÖÖÖDDoS¹¥»÷£¬£¬£¬£¬£¬ £¬ÍøÂçÓÉÓÚÆä¿ª·ÅÐÔ£¬£¬£¬£¬£¬ £¬¾­³£ÓÉÓÚÅÌËã»úѬȾ²¡¶¾£¬£¬£¬£¬£¬ £¬»òÊǽÓÈëÍøÂçµÄÖ°Ô±³öÓÚÖÖÖÖÄ¿µÄ¶ÔÍøÂç×°±¸¡¢ÍøÂçÖеķþÎñÆ÷¾ÙÐй¥»÷£¬£¬£¬£¬£¬ £¬µ¼ÖÂÍøÂçÎÞ·¨Õý³£Ê¹Óᣡ£¡£¡£¡£¡£½Ï³£¼ûµÄÈçARP·ººé¹¥»÷µ¼ÖÂÍø¹ØÎÞ·¨ÏìÓ¦ÇëÇó¡¢ICMP·ººé¹¥»÷µ¼ÖÂÍøÂç×°±¸CPU¸ºÔعý¸ßÎÞ·¨Õý³£ÊÂÇ飬£¬£¬£¬£¬ £¬DHCPÇëÇ󷺺鹥»÷£¬£¬£¬£¬£¬ £¬µ¼ÖÂDHCP·þÎñÆ÷µØÖ·¿Ý½ß£¬£¬£¬£¬£¬ £¬Óû§ÎÞ·¨Õý³£»£»£»£»£»£»ñÈ¡IPµØÖ·»á¼ûÍøÂç¡£¡£¡£¡£¡£¡£

RG-S5310ϵÁÐÌṩҵ½çÏȽøµÄÓ²¼þCPU±£»£»£»£»£»£»¤»úÖÆ£ºÌØÓеÄCPU±£»£»£»£»£»£»¤Õ½ÂÔ£¨CPP£¬£¬£¬£¬£¬ £¬CPU Protect Policy£©£¬£¬£¬£¬£¬ £¬¶Ô·¢ÍùCPUµÄÊý¾ÝÁ÷£¬£¬£¬£¬£¬ £¬¾ÙÐÐÁ÷Çø·ÖºÍÓÅÏȼ¶ÐÐÁзּ¶´¦Öóͷ££¬£¬£¬£¬£¬ £¬²¢Æ¾Ö¤ÐèҪʵÑé´øÍÑÆÚËÙ£¬£¬£¬£¬£¬ £¬³ä·Ö±£»£»£»£»£»£»¤CPU²»±»²»·¨Á÷Á¿Õ¼ÓᢶñÒâ¹¥»÷ºÍ×ÊÔ´ÏûºÄ£¬£¬£¬£¬£¬ £¬°ü¹ÜÁËCPUÇå¾²£¬£¬£¬£¬£¬ £¬³ä·Ö±£»£»£»£»£»£»¤Á˽»Á÷»úµÄÇå¾²¡£¡£¡£¡£¡£¡£

RG-S5310ϵÁÐÌṩÁ¢ÒìµÄ»ù´¡ÍøÂç±£»£»£»£»£»£»¤Õ½ÂÔ£¨NFPP£¬£¬£¬£¬£¬ £¬Network Foundation Protection Policy£©ÊÖÒÕ£¬£¬£¬£¬£¬ £¬Äܹ»ÏÞÖÆÓû§ÏòÍøÂçÖз¢ËÍARP±¨ÎÄ¡¢ICMPÇëÇó±¨ÎÄ¡¢DHCPÇëÇó±¨ÎĵÈÊý¾Ý°üµÄÊýÂÊ£¬£¬£¬£¬£¬ £¬¶ÔÁè¼ÝÏÞËÙãÐÖµµÄ±¨ÎľÙÐÐÑïÆú´¦Öóͷ££¬£¬£¬£¬£¬ £¬ÉõÖÁÄܹ»Ê¶±ð¹¥»÷ÐÐΪ£¬£¬£¬£¬£¬ £¬¶ÔÓй¥»÷ÐÐΪµÄÓû§¾ÙÐиôÀë¡£¡£¡£¡£¡£¡£´Ó¶ø±£»£»£»£»£»£»¤»ù´¡ÍøÂçÃâÊÜÍøÂç¹¥»÷ÐÐΪµÄÓ°Ï죬£¬£¬£¬£¬ £¬°ü¹ÜÍøÂçÎȹÌ¡£¡£¡£¡£¡£¡£

Ö§³ÖDHCP snooping£¬£¬£¬£¬£¬ £¬¿ÉÖ»ÔÊÐíÐÅÈζ˿ڵÄDHCPÏìÓ¦£¬£¬£¬£¬£¬ £¬±ÜÃâ˽ÉèDHCP ServerµÄÓÕÆ­£»£»£»£»£»£»²¢ÔÚDHCP¼àÌýµÄ»ù´¡ÉÏ£¬£¬£¬£¬£¬ £¬Í¨¹ý¶¯Ì¬¼à²âARPºÍ¼ì²éÓû§µÄIP£¬£¬£¬£¬£¬ £¬Ö±½ÓÑïÆú²»Çкϰ󶨱íÏîµÄ²»·¨±¨ÎÄ£¬£¬£¬£¬£¬ £¬ÓÐÓÃÌá·ÀARPÓÕÆ­ºÍÓû§Ô´IPµØÖ·µÄÓÕÆ­ÎÊÌâ¡£¡£¡£¡£¡£¡£

Ö§³Ö¶àÖÖÓªÒµÌØÕ÷

Ó²¼þÖ§³ÖIPv4/IPv6˫ЭÒéÕ»¶à²ãÏßËÙ½»Á÷£¬£¬£¬£¬£¬ £¬¿Éƾ֤IPv6ÍøÂçµÄÐèÇóÍýÏëºÍÉè¼ÆÍøÂ磬£¬£¬£¬£¬ £¬ÌṩÎÞаµÄIPv6ÍøÂçͨѶ¼Æ»®¡£¡£¡£¡£¡£¡£

Ö§³Ö¸»ºñµÄIPv4·ÓÉЭÒ飬£¬£¬£¬£¬ £¬°üÀ¨¾²Ì¬Â·ÓÉ¡¢RIP¡¢OSPFµÈ£¬£¬£¬£¬£¬ £¬Öª×ã²î±ðÍøÂçÇéÐÎÖÐÓû§Ñ¡ÔñºÏÊʵÄ·ÓÉЭÒéÎÞа×é½¨ÍøÂç¡£¡£¡£¡£¡£¡£

Ö§³Ö¸»ºñµÄIPv6·ÓÉЭÒ飬£¬£¬£¬£¬ £¬°üÀ¨¾²Ì¬Â·ÓÉ¡¢RIPng¡¢OSPFv3µÈ£¬£¬£¬£¬£¬ £¬ÆñÂÛÊÇÔÚÉý¼¶ÏÖÓÐÍøÂçÖÁIPv6ÍøÂ磬£¬£¬£¬£¬ £¬ÕÕ¾Éн¨IPv6ÍøÂ磬£¬£¬£¬£¬ £¬¶¼¿ÉÎÞаѡÔñºÏÊʵÄ·ÓÉЭÒé×é½¨ÍøÂç¡£¡£¡£¡£¡£¡£

ÐéÄâ½»Á÷µ¥Î»£¨VSU£¬£¬£¬£¬£¬ £¬Virtual Switching Unit£©

RG-S5310ϵÁвúÆ·Ö§³ÖVSU£¨Virtual Switch Unit£©¼´ÐéÄâ½»Á÷µ¥Î»ÊÖÒÕ¡£¡£¡£¡£¡£¡£Äܹ»½«¶ą̀ÎïÀí×°±¸¾ÙÐл¥Áª£¬£¬£¬£¬£¬ £¬Ê¹ÆäÐéÄâΪһ̨Âß¼­×°±¸£¬£¬£¬£¬£¬ £¬Ê¹Óüòµ¥IPµØÖ·¡¢¼òµ¥TelnetÀú³Ì¡¢¼òµ¥ÏÂÁîÐнӿڣ¨CLI£©¡¢×Ô¶¯°æ±¾¼ì²é¡¢×Ô¶¯ÉèÖõÈÌØÕ÷¾ÙÐйÜÀí£¬£¬£¬£¬£¬ £¬¶ÔÓû§À´Ëµ½ö½öÊÇÔÚ¹ÜÀíһ̨װ±¸£¬£¬£¬£¬£¬ £¬¿ÉÊÇȴʵÏÖ×Ŷą̀װ±¸´øÀ´µÄÊÂÇéЧÂʺÍʹÓÃÌåÑé¡£¡£¡£¡£¡£¡£

¼ò»¯¹ÜÀí£º¹ÜÀíÔ±¿ÉÒÔ¶Ô¶ą̀½»Á÷»úͳһ¹ÜÀí£¬£¬£¬£¬£¬ £¬¶ø²»ÐèÒªÅþÁ¬µ½Ã¿Ì¨½»Á÷»ú»®·Ö¾ÙÐÐÉèÖú͹ÜÀí¡£¡£¡£¡£¡£¡£

¼ò»¯ÍøÂçÍØÆË£ºVSUÔÚÍøÂçÖÐÏ൱ÓÚһ̨½»Á÷»ú£¬£¬£¬£¬£¬ £¬Í¨¹ý¾ÛºÏÁ´Â·ºÍÍâΧװ±¸ÅþÁ¬£¬£¬£¬£¬£¬ £¬²»±£´æ¶þ²ã»·Â·£¬£¬£¬£¬£¬ £¬Ã»ÐëÒªÉèÖÃMSTPЭÒ飬£¬£¬£¬£¬ £¬ÖÖÖÖ¿ØÖÆÐ­ÒéÊÇ×÷Ϊһ̨½»Á÷»úÔËÐеÄ¡£¡£¡£¡£¡£¡£

ºÁÃë¼¶¹ÊÕϻָ´£ºVSUºÍÍâΧװ±¸Í¨¹ý¾ÛºÏÁ´Â·ÅþÁ¬£¬£¬£¬£¬£¬ £¬ÈôÊÇÆäÖÐһ̨װ±¸»òÕßÒ»Ìõ³ÉÔ±Á´Â··ºÆð¹ÊÕÏ£¬£¬£¬£¬£¬ £¬Çл»µ½ÁíÒ»Ìõ³ÉÔ±Á´Â·µÄʱ¼äÖ»ÐèÒª50µ½200ºÁÃë¡£¡£¡£¡£¡£¡£

¸ßÀ©Õ¹ÐÔ£ºÓû§ÐÂÔöµÄ×°±¸¼ÓÈë»òÍÑÀëÐéÄâ»¯ÍøÂçʱ¿ÉÒÔʵÏÖ“ÈȲå°Î”£¬£¬£¬£¬£¬ £¬²»Ó°ÏìÆäËû×°±¸µÄÕý³£ÔËÐС£¡£¡£¡£¡£¡£

±£»£»£»£»£»£»¤Í¶×Ê£ºVSUºÍÍâΧװ±¸Í¨¹ý¾ÛºÏÁ´Â·ÅþÁ¬£¬£¬£¬£¬£¬ £¬¼ÈÌṩÁËÈßÓàÁ´Â·£¬£¬£¬£¬£¬ £¬ÓÖ¿ÉÒÔʵÏÖ¸ºÔØÆ½ºâ£¬£¬£¬£¬£¬ £¬³ä·ÖʹÓÃËùÓÐÍøÂç×°±¸ºÍ´ø¿í×ÊÔ´¡£¡£¡£¡£¡£¡£Í¬Ê±¿ÉÓÃí§ÒâÐÎ̬µÄÍòÕ×¶Ë¿Úͨ¹ýí§ÒâµÄÊý¾Ý´«ÊäÏßÀÂ×é³ÉVSUÐéÄâÍøÂçϵͳ£¬£¬£¬£¬£¬ £¬²»ÐèÒªÌØÊâÉèÖÃÏßÀ¡¢À©Õ¹¿¨£¬£¬£¬£¬£¬ £¬²¢ÇÒûÓж˿ںÍÏßÀÂÖÖÀàµÄÏÞÖÆ£¬£¬£¬£¬£¬ £¬ÓÐÓñ£»£»£»£»£»£»¤Óû§µÄͶ×Ê¡£¡£¡£¡£¡£¡£

¸ß¿É¿¿ÐÔ

Ö§³ÖÌìÉúÊ÷ЭÒéSTP¡¢RSTP¡¢MSTP£¬£¬£¬£¬£¬ £¬°ü¹Ü¿ìËÙÊÕÁ²£¬£¬£¬£¬£¬ £¬Ìá¸ßÈÝ´íÄÜÁ¦£¬£¬£¬£¬£¬ £¬°ü¹ÜÍøÂçµÄÎȹÌÔËÐкÍÁ´Â·µÄ¸ºÔØÆ½ºâ£¬£¬£¬£¬£¬ £¬ºÏÀíʹÓÃÍøÂçͨµÀ£¬£¬£¬£¬£¬ £¬ÌṩÈßÓàÁ´Â·Ê¹ÓÃÂÊ¡£¡£¡£¡£¡£¡£

Ö§³ÖÐéÄâ·ÓÉÆ÷ÈßÓàЭÒ飨VRRP£©£¬£¬£¬£¬£¬ £¬ÓÐÓðü¹ÜÍøÂçÎȹÌ¡£¡£¡£¡£¡£¡£

Ö§³Ö¿ìËÙÁ´Â·¼ì²âЭÒ飨RLDP£¬£¬£¬£¬£¬ £¬Rapid Link Detection Protocol£©£¬£¬£¬£¬£¬ £¬¿É¿ìËÙ¼ì²âÁ´Â·µÄͨ¶ÏºÍ¹âÏËÁ´Â·µÄµ¥ÏòÐÔ£¬£¬£¬£¬£¬ £¬²¢Ö§³Ö¶Ë¿ÚÏµĻ·Â·¼ì²â¹¦Ð§£¬£¬£¬£¬£¬ £¬±ÜÃâ¶Ë¿ÚÏÂÒò˽½ÓHubµÈ×°±¸ÐγɵĻ·Â·¶øµ¼ÖÂÍøÂç¹ÊÕϵÄÕ÷Ï󡣡£¡£¡£¡£¡£

Ö§³Ö¹«ÓÐÒÔÌ«Íø¶à»·±£»£»£»£»£»£»¤ÊÖÒÕ£¨ERPS£©£¬£¬£¬£¬£¬ £¬¹ú¼Ê±ê׼Ϊ½¹µãÒÔÌ«ÍøÉè¼ÆµÄ¶þ²ãÁ´Â·ÈßÓ౸·ÝЭÒ飬£¬£¬£¬£¬ £¬Æä»·Â·×è¶ÏÒÔ¼°Á´Â·»Ö¸´¶¼¼¯ÖÐÔÚÖ÷¿Ø×°±¸ÉϾÙÐУ¬£¬£¬£¬£¬ £¬·ÇÖ÷¿Ø×°±¸Ö±½ÓÏòÖ÷¿Ø×°±¸»ã±¨×Ô¼ºµÄÁ´Â·ÇéÐΣ¬£¬£¬£¬£¬ £¬ÎÞÐè¾­ÓÉÆäËû·ÇÖ÷¿Ø×°±¸µÄ´¦Öóͷ££¬£¬£¬£¬£¬ £¬Òò´Ë»·Â·ÖÐÖ¹ÒÔ¼°»Ö¸´Ê±¼ä±ÈSTP¿ì¡£¡£¡£¡£¡£¡£»£»£»£»£»£»ùÓÚÒÔÉÏÇø±ð£¬£¬£¬£¬£¬ £¬ERPSÔÚÀíÏëÇéÐÎϵÄÁ´Â·»Ö¸´ÄÜÁ¦Äܹ»µÖ´ïºÁÃë¼¶¡£¡£¡£¡£¡£¡£

ÔÚ²»ÆôÓÃSTPµÄÇéÐÎÏ£¬£¬£¬£¬£¬ £¬¿ÉÒÔͨ¹ý¿ìËÙÉÏÁ´±£»£»£»£»£»£»¤Ð­Ò飨REUP£¬£¬£¬£¬£¬ £¬Rapid Ethernet Uplink Protection Protocol£©£¬£¬£¬£¬£¬ £¬Ìṩһ¸ö¿ìËÙÉÏÁ´±£»£»£»£»£»£»¤¹¦Ð§£¬£¬£¬£¬£¬ £¬REUPʹµÃÓû§ÔڹرÕSTPµÄÇéÐÎÏ£¬£¬£¬£¬£¬ £¬ÈÔÌṩ»ù±¾µÄÁ´Â·ÈßÓ࣬£¬£¬£¬£¬ £¬Í¬Ê±Ìṩ±ÈSTP¸ü¿ìµÄºÁÃë¼¶¹ÊÕϻָ´¡£¡£¡£¡£¡£¡£

²úÆ·Òªº¦²¿Î»Í¿¸²Èý·ÀÆá£¬£¬£¬£¬£¬ £¬ÐγÉÒ»²ã±£»£»£»£»£»£»¤Ä¤£¬£¬£¬£¬£¬ £¬ÔöÇ¿·À»¤£¬£¬£¬£¬£¬ £¬ÌáÉý±°ÁÓÇéÐÎϵĿɿ¿ÐÔ£¬£¬£¬£¬£¬ £¬×°±¸Ö§³Ö¸ß´ï10KVµÄ¶Ë¿Ú·ÀÀ×ÄÜÁ¦£¬£¬£¬£¬£¬ £¬°ü¹ÜÔÚÖÖÖÖ±°ÁÓÇéÐÎÏÂÎȹÌÊÂÇé¡£¡£¡£¡£¡£¡£

Èí¼þ½çËµÍøÂ磨SDN£©

RG-S5310ϵÁвúÆ·×·ËæÊ±´úÉú³¤£¬£¬£¬£¬£¬ £¬Ö§³ÖOpenFlow 1.3£¬£¬£¬£¬£¬ £¬¿ÉÒÔºÍstake¹ÙÍøÍøÂç×ÔÑÐSDN controller Ï໥ÅäºÏ£¬£¬£¬£¬£¬ £¬ÇáËÉʵÏÖ´ó¹æÄ£¶þ²ã¼Ü¹¹×éÍø£¬£¬£¬£¬£¬ £¬²¢ÇÒÖ§³ÖÕûÍøÆ½»¬Éý¼¶µ½SDNÍøÂ磬£¬£¬£¬£¬ £¬ÔÚ´ó·ù¼ò»¯ÍøÂç¹ÜÀíµÄÄѶȵÄͬʱ¿ÉÏÔÖø½µµÍÍøÂçά»¤µÄ±¾Ç®¡£¡£¡£¡£¡£¡£

ÂÌÉ«½ÚÄÜ

RG-S5310ϵÁн»Á÷»úÖ§³Ö¶Ë¿Ú×Ô¶¯½ÚÄÜ£¬£¬£¬£¬£¬ £¬ÈôÊÇÔÚÒ»¶Îʱ¼äÄÚ½Ó¿Ú״̬ʼÖÕΪdown£¬£¬£¬£¬£¬ £¬Ôòϵͳ×Ô¶¯×èÖ¹¶Ô¸Ã½Ó¿Ú¹©µç£¬£¬£¬£¬£¬ £¬×Ô¶¯½øÈë½ÚÄÜģʽ£»£»£»£»£»£»Í¬Ê±Ö§³Ö¸ßЧ½ÚÄÜÒÔÌ«Íø£¨EEE£©£¬£¬£¬£¬£¬ £¬¶Ë¿ÚÈôÊÇÔÚÒ»Á¬Ò»¶Îʱ¼äÖ®ÄÚ¿ÕÏУ¬£¬£¬£¬£¬ £¬ÏµÍ³»á½«¸Ã¶Ë¿ÚÉèÖÃΪ½ÚÄÜģʽ£¬£¬£¬£¬£¬ £¬µ±Óб¨ÎÄÊÕ·¢Ê±ÔÙͨ¹ý׼ʱ·¢Ë͵ļàÌýÂëÁ÷½ÐÐѶ˿ڻָ´ÓªÒµ£¬£¬£¬£¬£¬ £¬µÖ´ï½ÚÄܵÄЧ¹û¡£¡£¡£¡£¡£¡£

RG-S5310ϵÁвúƷͬʱ֪×ãÖÊÁÏ»·±£ÓëÇå¾²ÐÔµÄÅ·ÃËRoHS±ê×¼¡£¡£¡£¡£¡£¡£

¼òÆÓÇáËɵÄÍøÂçά»¤

RG-S5310ϵÁÐÖ§³ÖSNMP¡¢RMON¡¢Syslog¡¢USB±¸·ÝÈÕÖ¾¼°ÉèÖõÈÌØÕ÷À´¾ÙÐÐÍøÂçµÄÒ»Ñùƽ³£Õï¶Ï¼°Î¬»¤£¬£¬£¬£¬£¬ £¬Í¬Ê±¹ÜÀíÔ±¿É½ÓÄÉÏÂÁîÐнӿÚ(CLI)¡¢WebÍø¹Ü¡¢TelnetµÈ¶àÑù»¯µÄ¹ÜÀíºÍά»¤·½·¨¸üÀû±ã×°±¸µÄ¹ÜÀí¡£¡£¡£¡£¡£¡£

ÊÖÒÕ²ÎÊý

²úÆ·ÐͺÅ

RG-S5310-24GT4XS

RG-S5310-48GT4XS

»ù±¾ÌØÕ÷

Àο¿¶Ë¿Ú

24¸ö10/100/1000M×Ô˳Ӧµç¿Ú£¬£¬£¬£¬£¬ £¬4¸ö1G/10G SFP+¹â¿Ú£¬£¬£¬£¬£¬ £¬2¸öÄ£¿£¿£¿£¿£¿£¿é»¯µçÔ´²å²Û

48¸ö10/100/1000M×Ô˳Ӧµç¿Ú£¬£¬£¬£¬£¬ £¬4¸ö1G/10G SFP+¹â¿Ú£¬£¬£¬£¬£¬ £¬2¸öÄ£¿£¿£¿£¿£¿£¿é»¯µçÔ´²å²Û

½»Á÷ÈÝÁ¿

688Gbps/6.88Tbps

°üת·¢ÂÊ

171Mpps/297Mpps

207Mpps/363Mpps

×î´ó¹¦ºÄ

27W

48W

¶þ²ãÌØÕ÷

MACµØÖ·±í

Ö§³Ö¾²Ì¬MACµØÖ·

Ö§³ÖMACµØÖ·¹ýÂË

802.1Q VLAN

Ö§³Ö4K 802.1Q VLAN

Ö§³ÖPort based VLAN

Ö§³ÖMAC based VLAN

Ö§³ÖProtocol based VLAN

Ö§³ÖPrivate VLAN

Ö§³ÖVoice VLAN

Ö§³ÖIP subnet-based VLAN

Ö§³ÖGVRP

QinQ

Ö§³Ö»ù±¾QinQ

Ö§³ÖÎÞаQinQ

¶Ë¿Ú¾µÏñ

Ö§³ÖÒ»¶ÔÒ»¡¢¶à¶ÔÒ»¡¢Ò»¶Ô¶àµÄ¾µÏñ

Ö§³ÖRSPAN¡¢ERSPAN

Ö§³Ö»ùÓÚÁ÷µÄ¾µÏñ

ACL

Ö§³Ö±ê×¼IP ACL£¨»ùÓÚIPµØÖ·µÄÓ²¼þACL£©

Ö§³ÖÀ©Õ¹IP ACL£¨»ùÓÚIPµØÖ·¡¢TCP/UDP¶Ë¿ÚºÅµÄÓ²¼þACL£©

Ö§³ÖMACÀ©Õ¹ACL£¨»ùÓÚÔ´MACµØÖ·¡¢Ä¿µÄMACµØÖ·ºÍ¿ÉÑ¡µÄÒÔÌ«ÍøÀàÐ͵ÄÓ²¼þACL£©

Ö§³Ö»ùÓÚʱ¼äACL

Ö§³Öר¼Ò¼¶ACL £¨¿Éͬʱ»ùÓÚVLANºÅ¡¢ÒÔÌ«ÍøÀàÐÍ¡¢MACµØÖ·¡¢IPµØÖ·¡¢TCP/UDP¶Ë¿ÚºÅ¡¢Ð­ÒéÀàÐÍ¡¢Ê±¼äµÈÎÞа×éºÏµÄÓ²¼þACL£©

Ö§³ÖACL80

Ö§³ÖIPv6 ACL

Ö§³ÖÈ«¾ÖACL

Ö§³ÖACLÖØ¶¨Ïò

QoS

Ö§³Ö¶Ë¿ÚÁ÷Á¿Ê¶±ð

Ö§³Ö¶Ë¿ÚÁ÷Á¿ÏÞËÙ

Ö§³Ö802.1Q/DSCP/TOSÁ÷Á¿·ÖÀà

ÿ¶Ë¿Ú8¸öÓÅÏȼ¶ÐÐÁÐ

Ö§³ÖSP¡¢WRR¡¢DRR¡¢SP+WFQ¡¢ SP+WRR¡¢SP+DRR¡¢RED/WREDÐÐÁе÷Àí

DHCP

Ö§³ÖDHCP Server

Ö§³ÖDHCP Client

Ö§³ÖDHCP Snooping

Ö§³ÖDHCP Relay

Ö§³ÖIPv6 DHCP Snooping

Ö§³ÖIPv6 DHCP Client

Ö§³ÖIPv6 DHCP Relay

Çå¾²ÌØÕ÷

Ö§³ÖIP¡¢MAC¡¢¶Ë¿ÚÈýÔªËØ°ó¶¨

Ö§³ÖIPv6¡¢MAC¡¢¶Ë¿ÚÈýÔªËØ°ó¶¨

¹ýÂ˲»·¨µÄMACµØÖ·

Ö§³Ö»ùÓڶ˿ںÍMACµÄ802.1x

Ö§³ÖMAB

Ö§³ÖPortal ºÍPortal 2.0ÈÏÖ¤

Ö§³ÖARP Check

Ö§³ÖDAI

Ö§³ÖARP±¨ÎÄÏÞËÙ

Ö§³Ö·ÀÍø¹ØARPÓÕÆ­

Ö§³Ö¹ã²¥·ç±©ÒÖÖÆ

¹ÜÀíÔ±·Ö¼¶¹ÜÀíºÍ¿ÚÁî±£»£»£»£»£»£»¤

Ö§³ÖRadius ºÍ TACACS+

×°±¸Éϰ¶¹ÜÀíµÄAAAÇå¾²ÈÏÖ¤£¨IPv4/IPv6£©

Ö§³ÖSSH ºÍ SSH V2.0

Ö§³ÖBPDU Guard

Ö§³ÖIP Source Guard

Ö§³ÖCPP¡¢NFPP

Ö§³Ö¶Ë¿Ú±£»£»£»£»£»£»¤

ÏßÀ¼ì²â

Ö§³ÖÏßÀ¼ì²â

EEE

Ö§³Ö±ê×¼µÄ EEE½ÚÄÜÊÖÒÕ£ºµ±EEEʹÄÜʱ£¬£¬£¬£¬£¬ £¬´Ó¶ø´ó·ù¶ÈµÄ¼õС¶Ë¿ÚÔڸý׶εŦºÄ£¬£¬£¬£¬£¬ £¬µÖ´ïÁ˽ÚÄܵÄÄ¿µÄ¡£¡£¡£¡£¡£¡£

¶Ë¿ÚÐÝÃß

Ö§³Ö¶Ë¿ÚÐÝÃß

Èý²ãÌØÕ÷

IP·ÓÉ

IPv4/IPv6 ¾²Ì¬Â·ÓÉ

RIP¡¢RIPng

OSPFv2¡¢OSPFv3

Routing Policy

IPv6»ù´¡Ð­Òé

IPv6±àÖ·¡¢ÁÚÈË·¢Ã÷ЭÒ飨ND£©¡¢ICMPv6¡¢IPv6 Ping¡¢IPv6 TracertµÈ

VSUÌØÕ÷

Ö§³ÖVSUÐéÄ⻯ÊÖÒÕ

Ö§³ÖÍâµØ¶ÑµþºÍÔ¶³Ì¶Ñµþ

Ö§³Ö¶ÑµþÄÚ¿ç»úÏäµÄÁ´Â·À¦°ó

Ö§³Öͨ¹ý±ê×¼½Ó¿Ú¾ÙÐжѵþ

¹ÜÀíÌØÕ÷

SNMPv1/v2c/v3¡¢CLI(Telnet/Console)¡¢RMON¡¢SSH¡¢Syslog¡¢NTP/SNTP¡¢FTP¡¢TFTP¡¢Web

ÎïÀíÌØÕ÷

²úÆ·³ß´ç£¨¿íxÉîx¸ß£©

V1.XX°æ±¾£º

440.0mm x 246.1mm x 43.6mm

V2.XX¼°ÒÔÉϰ汾£º

440.0mm x 238.6mm x 43.6mm

V1.XX°æ±¾£º

440.0mm x 347.6mm x 43.6mm

V2.XX¼°ÒÔÉϰ汾£º

440.0mm x 342.0mm x 43.6mm

µçÔ´

½»Á÷£¨AC£©ÊäÈ룺

¶î¶¨µçѹ¹æÄ££º100V~240V

×î´óµçѹ¹æÄ££º90V~264V

ƵÂÊ£º50/60Hz

 

¸ßѹֱÁ÷(HVDC)ÊäÈ룺

¶î¶¨µçѹ¹æÄ££º240V

×î´óµçѹ¹æÄ££º192~288V

 

Ö±Á÷£¨DC£©ÊäÈ룺

¶î¶¨µçѹ¹æÄ££º-36~-72VDC

µçÉÈ

Ö§³ÖµçÉȵ÷ËÙ¼°µçÉȹÊÕϸ澯¹¦Ð§

ζÈ

ÊÂÇéζȣº0¡æ~50¡æ

´æ´¢Î¶ȣº-40¡æ~70¡æ

ʪ¶È

ÊÂÇéʪ¶È£º10%~90%RH

´æ´¢Êª¶È£º5%~95%RH

 

£¨*£©ÌåÏÖºóÐøÖ§³Ö

Õö¿ªÏêϸ²ÎÊý

×ÊÔ´ÖÐÐÄ

ÓªÏú×ÊÁÏ
Ó¦Óð¸Àý
ÊÖÒÕ²©ÎÄ
ÊÛºóÎĵµ

³£¼ûÎÊÌâ

ÎÒÒªÌáÎÊ
ËùÓÐ
PoE¹©µç(1)
»·Â·¼ì²â(1)
stake¹ÙÍø 2022Äê07ÔÂ25ÈÕ
RG-S5310-24GT4XS-P-EÖ§³ÖPoEÂ𣿣¿£¿£¿£¿£¿
ÓÐÓÃ 26 ÎÞÓÃ 2

¸ÃϵÁÐÔÚÃüÃûÖÐÓÐ-PµÄ£¬£¬£¬£¬£¬ £¬¶¼ÊÇÖ§³ÖPOE¹©µçµÄ¡£¡£¡£¡£¡£¡£

stake¹ÙÍø 2022Äê07ÔÂ25ÈÕ
½»Á÷»úµÄ»·Â·¼ì²âÔõôʵÏÖµÄÄØ£¿£¿£¿£¿£¿£¿
ÓÐÓÃ 518 ÎÞÓÃ 70

ͨ¹ýstake¹ÙÍø×ÔÖ÷Ñз¢µÄÓÃÓÚ¿ìËÙ¼ì²âÒÔÌ«ÍøÁ´Â·¹ÊÕϵÄÁ´Â·Ð­Òé——RLDP À´ÊµÏֵġ£¡£¡£¡£¡£¡£
Ò»Ñùƽ³£µÄÒÔÌ«ÍøÁ´Â·¼ì²â»úÖÆ¶¼Ö»ÊÇʹÓÃÎïÀíÅþÁ¬µÄ״̬£¬£¬£¬£¬£¬ £¬Í¨¹ýÎïÀí²ãµÄ×Ô¶¯Ð­ÉÌÀ´¼ì²âÁ´Â·µÄÁ¬Í¨ÐÔ¡£¡£¡£¡£¡£¡£
¿ÉÊÇÕâÖÖ¼ì²â»úÖÆ±£´æÒ»¶¨µÄ¾ÖÏÞÐÔ£¬£¬£¬£¬£¬ £¬ÔÚһЩÇéÐÎÏÂÎÞ·¨ÎªÓû§Ìṩ¿É¿¿µÄÁ´Â·¼ì²âÐÅÏ¢£¬£¬£¬£¬£¬ £¬ºÃ±ÈÔÚ¹âÏË¿ÚÉϹâÏËÎüÊÕÏß¶Ô½Ó´í£¬£¬£¬£¬£¬ £¬ÓÉÓÚ¹âÏËת»»Æ÷µÄ±£´æ£¬£¬£¬£¬£¬ £¬Ôì³É×°±¸¶ÔÓ¦¶Ë¿ÚÎïÀíÉÏÊÇlinkup µÄ£¬£¬£¬£¬£¬ £¬µ«ÏÖʵ¶ÔÓ¦µÄ¶þ²ãÁ´Â·È´ÊÇÎÞ·¨Í¨Ñ¶µÄ¡£¡£¡£¡£¡£¡£ÔٺñÈÁ½Ì¨ÒÔÌ«Íø×°±¸Ö®¼ä¼ÜÉè×ÅÒ»ÆäÖÐÐÄÍøÂ磬£¬£¬£¬£¬ £¬ÓÉÓÚÍøÂç´«ÊäÖмÌ×°±¸µÄ±£´æ£¬£¬£¬£¬£¬ £¬ÈôÊÇÕâЩÖмÌ×°±¸·ºÆð¹ÊÕÏ£¬£¬£¬£¬£¬ £¬½«Ôì³ÉͬÑùµÄÎÊÌâ¡£¡£¡£¡£¡£¡£
ʹÓÃRLDP ЭÒéÓû§½«¿ÉÒÔÀû±ã¿ìËٵؼì²â³öÒÔÌ«Íø×°±¸µÄÁ´Â·¹ÊÕÏ£¬£¬£¬£¬£¬ £¬°üÀ¨µ¥ÏòÁ´Â·¹ÊÕÏ¡¢Ë«ÏòÁ´Â·¹ÊÕÏ¡¢»·Â·Á´Â·¹ÊÕÏ¡£¡£¡£¡£¡£¡£

Õö¿ªËùÓÐ
ÈôÊÇÄúÐèÒª¸ü¶à²úÆ·ÊÖÒÕ×Éѯ
ÏêϸÐÔÄÜÄÜ·ñÖª×ãÄúµÄÓªÒµ·åÖµ£¿£¿£¿£¿£¿£¿ÔõÑùÍýÏë°²ÅÅÓëÉèÖã¿£¿£¿£¿£¿£¿
Á¬Ã¦×Éѯ
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾

·µ»Ø¶¥²¿

ÊÕÆð
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾ ÎĵµAIÖúÊÖ
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾ ÎĵµÆÀ¼Û
¸Ã×ÊÁÏÊÇ·ñ½â¾öÁËÄúµÄÎÊÌ⣿£¿£¿£¿£¿£¿
Äú¶ÔÄ¿½ñÒ³ÃæµÄÖª×ã¶ÈÔõÑù£¿£¿£¿£¿£¿£¿
²»Õ¦µÎ
ºÜÊǺÃ
ÄúÖª×ãµÄÔµ¹ÊÔ­ÓÉÊÇ£¨¶àÑ¡£¡£¡£¡£¡£¡£©£¿£¿£¿£¿£¿£¿
Äú¶ÔÎĵµÊÇ·ñÉÐÓÐÆäËüµÄÎÊÌâ»ò½¨Ò飿£¿£¿£¿£¿£¿
Ϊ¾¡¿ì½â¾öÎÊÌ⣬£¬£¬£¬£¬ £¬ÇëÄúÁôÏÂÁªÏµ·½·¨Òﱋȯ¸´
ÓÊÏä
ÊÖ»úºÅ
ллÄúµÄ·´À¡£¡£¡£¡£¡£¡£¡
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾
Stake(ÖйúÇø)¹Ù·½ÍøÕ¾
ÇëÑ¡Ôñ·þÎñÏîÄ¿
¹Ø±Õ×Éѯҳ
ÊÛǰ×Éѯ ÊÛǰ×Éѯ
ÊÛǰ×Éѯ
ÊÛºó·þÎñ ÊÛºó·þÎñ
ÊÛºó·þÎñ
Òâ¼û·´Ïì Òâ¼û·´Ïì
Òâ¼û·´Ïì
¸ü¶àÁªÏµ·½·¨
ÍøÕ¾µØÍ¼